[Zurück]


Vorträge und Posterpräsentationen (mit Tagungsband-Eintrag):

E. Robeischl, M. Schrödl, K. Salutt, U. Rieder:
"Automatic statistical INFORM-parameter detection of sensorless permanent magnet synchronous drives without test stand and reference position measurement";
Vortrag: International Conference on Power Conversion and Intelligent Motion (PCIM), Nuremberg, Germany; 14.05.2002 - 16.05.2002; in: "Proceedings of the thirty-ninth International Intelligent Motion", (2002), ISBN: 3-928643-31-2; S. 187 - 192.



Kurzfassung englisch:
For sensorless saliency based INFORM-position estimation of Permanent Magnet Synchronous Motors the standard deviation and the load dependence of the estimated position are of significant importance. To determine these quantities there is conventionally the need for a reference position measurement and a loading test stand. However, in the presented paper these quantities are measured without coupling of any hardware components resulting in a remarkably minimised time and hardware effort for INFORM-performance determination of different industrial motors