M. Schrödl, M. Lambeck, E. Robeischl:
"Implementation of the IMFORM method in a commercial converter for sensorless PM synchronous drives";
Vortrag: PCIM (Power Conversion, Intelligent Motion, Power Quality), Nürnberg, Germany; 14.05.2002 - 16.05.2002; in: "Proceedings of the thirty-ninth International Intelligent Motion", (2002), S. 135 - 140.



Kurzfassung englisch:
This paper describes how the INFORM method for position detection was first implemented in a commercial converter. The INFORM method is presented in comparison with other sensorless control principles. Possibilities to overcome the 180° error inherent in the system and the low sensitivity to parameter variation are discussed. A summary of hardware requirements and an outlook to future developments are also given.