[Zurück]


Vorträge und Posterpräsentationen (mit Tagungsband-Eintrag):

M. Wieger, H. Hauser:
"Electromagnetic Regeneration of Lead Acid Batteries";
Poster: 9th Int. Symposium on Non-Linear Electromagnetic Systems (ISEM), Pavia, Italy; 10.05.1999 - 12.05.1999; in: "ISEM 99 - Abstracts", (1999), S. 50.



Kurzfassung englisch:
Lead acid batteries loose their nominal capacity by time due to the normal aging and by sulfatation. More than 500 experiments proved that batteries regain more than 85% of their capacity being regenerated by the described electromagnetic procedure. Results on strongly sulfated lead acid batteries with a loss of capacity more than 90% show a success rate of more than 55%. Doing the regeneration with lead acid batteries which are still functional (loss of capacity less than 20%), showed that 95% of the nominal capacity could be achieved.

Erstellt aus der Publikationsdatenbank der Technischen Universität Wien.