F. Himmelstoß, P. Wurm, H. Hauser:
"Magnetic Measurement and Modelling of a DC-DC Converter Start-Up";
Vortrag: Magnetic Measurements 2000,
Prag, Tschechien;
11.09.2000
- 12.09.2000; in: "Proceedings",
(2000),
S. 9
- 11.
Kurzfassung englisch:
The use of tapped inductors in the classical buck-boost converter leads to higher step-up ratio thus avoiding the extreme duty cycles of the active switch and the high peak currents in the active and passive switches. The function and some stress data of such a converter are summarized and the flux density and the current through the inductor during start-up are measured and simulated.