Talks and Poster Presentations (with Proceedings-Entry):
F. Himmelstoß, P. Wurm, H. Hauser:
"Magnetic Measurement and Modelling of a DC-DC Converter Start-Up";
Talk: Magnetic Measurements 2000,
Prag, Tschechien;
09-11-2000
- 09-12-2000; in: "Proceedings",
(2000),
9
- 11.
English abstract:
The use of tapped inductors in the classical buck-boost converter leads to higher step-up ratio thus avoiding the extreme duty cycles of the active switch and the high peak currents in the active and passive switches. The function and some stress data of such a converter are summarized and the flux density and the current through the inductor during start-up are measured and simulated.
Created from the Publication Database of the Vienna University of Technology.