[Back]


Talks and Poster Presentations (with Proceedings-Entry):

E. Robeischl, M. Schrödl, K. Salutt:
"Improved INFORM-measurement sequence and evaluation for sensorless permanent magnet synchronous motor drives";
Talk: International Conference on Power Electronics and Motion Control, EPE-PEMC, Cavtat,Dubrovnik, Croatia; 2002-09-09 - 2002-09-11; in: "Proceedings of the 10th international power electronics & motion control conference", (2002), ISBN: 953-184-047-4; 1 - 7.



English abstract:
For INFORM-based sensorless position estimation with conventional current sensors the current control is interrupted in certain time intervals. During the so called INFORM-measurement, definite voltage space phasors are applied to the machine and the resulting current response is measured. A suitable evaluation of the measured quantities yields the required rotor position. The basic idea of the presented paper is to minimise the INFORM-measurement with respect to its duration and its repetition rate. Combining the improved measurement sequence with a corresponding modified evaluation a high quality position estimation is obtained at significantly reduced current distortion compared to the previous measurement sequence.