Talks and Poster Presentations (with Proceedings-Entry):
M. Schrödl, M. Lambeck, E. Robeischl:
"Implementation of the IMFORM method in a commercial converter for sensorless PM synchronous drives";
Talk: PCIM (Power Conversion, Intelligent Motion, Power Quality),
Nürnberg, Germany;
05-14-2002
- 05-16-2002; in: "Proceedings of the thirty-ninth International Intelligent Motion",
(2002),
135
- 140.
English abstract:
This paper describes how the INFORM method for position detection was first implemented in a commercial converter. The INFORM method is presented in comparison with other sensorless control principles. Possibilities to overcome the 180° error inherent in the system and the low sensitivity to parameter variation are discussed. A summary of hardware requirements and an outlook to future developments are also given.
Created from the Publication Database of the Vienna University of Technology.