A. Korjenic, J. Dreyer, T. Bednar, C. Hecht:
"Kapillaraufsteigende Mauerwerksfeuchtigkeit - Performancebewertung von Sanierungsvarianten";
WTA-Journal (invited), Jg. 1 (2003), 3; 229 - 271.



English abstract:
In this examination, an investigation method was developed, in order to be able to select the correct surface systems for walls with raising damp. The qualities of the surface system are chosen to prevent damages due to moisture without inserting a horizontal barricade. Different surface systems on the exterior and interior side were examined, in order to estimate their influence on the temperature and moisture development at the surface of the wall construction, the wall itself and the impact on the indoor climate of the adjacent room.

German abstract:
Im Rahmen dieser Untersuchung wurde ein Berechnungsmodell entwickelt, um das richtige Oberflächensystem mit entsprechenden Eigenschaften auswählen zu können und dadurch eine Schädigung infolge aufsteigender Feuchtigkeit zu verhindern, ohne dass eine Horizontalsperre eingebracht werden muss. Es sind verschiedene Oberflächensysteme auf der Außen- und Innenseite untersucht worden, um deren Einfluss auf den Temperatur- und Feuchtigkeitsverlauf an der Oberfläche der Wandkonstruktion und in der Wand selbst, sowie auf das Innenklima des angrenzenden Raumes zu analysieren.