[Back]


Talks and Poster Presentations (with Proceedings-Entry):

T. Bednar, J. Dreyer:
"Determination of moisture surface transfer coefficients under transient conditions";
Talk: Second International Building Physics Conference, Leuven; 2003-09-14 - 2003-09-18; in: "Research in Building Physics", (2003), ISBN: 90-5809-565-7; 233 - 236.



English abstract:
Detailed investigations on surface transfer coefficients for indoor environments under nonstationery conditions, like short term airing, are presented in the paper. The measurement method is carefully investigated to minimize the influence of uneven surface temperature profiles. A small (4x4x2 cm³) insulated specimen with a high liquid conductivity is the best probe for determination of the surface transfer coefficients. From the experiments it can be concluded that under winter conditions the moisture transfer coefficient is increased by 180% from its value with closed windows and that it takes two hours after the windows have been closed till it reaches its old value.


Online library catalogue of the TU Vienna:
http://aleph.ub.tuwien.ac.at/F?base=tuw01&func=find-c&ccl_term=AC04403325


Created from the Publication Database of the Vienna University of Technology.