[Zurück]


Zeitschriftenartikel:

M. Reiterer, F. Ziegler:
"Control of pedestrian-induced vibrations of long span bridges";
Structural Control & Health Monitoring, 13 (2006), 6; S. 1003 - 1027.



Kurzfassung englisch:
Sealed tuned liquid column dampers, with a gas spring effect taken into account are ideally suited to increase the effective structural damping of bridges vibrating in the low frequency band up to about five Hertz. Modal tuning in analogy to the classical mechanical damper followed by fine-tuning in state space, render the parameter optimal and the control more robust. Sufficient conditions to prevent parametric resonance of vertical motions of the TLCD and to avoid the synchronization effect of densely walking pedestrians on the lateral bridge vibrations are presented. Numerical simulations are experimentally checked for a novel laboratory model. Effective structural damping of the Millennium Bridge by five TLCD and of the Toda Park Bridge by a single TLCD is worked out in detail.


Online-Bibliotheks-Katalog der TU Wien:
http://aleph.ub.tuwien.ac.at/F?base=tuw01&func=find-c&ccl_term=AC06585522


Erstellt aus der Publikationsdatenbank der Technischen Universität Wien.