English abstract:
At a relatively small test specimen rising moisture can be simulated in the laboratory very close to reality. Necessary is a section-wise sealing, a temporally limited addition of water and a measuring of the evaporation of the humidity. The specimen can be controlled completely over a long period and during the measurements no changes are necessary. A calculation takes place in order to arrive this partial sealing and the temporary addition of humidity.
The contribution contains the description of the experimental setup, the documentation of the simulation calculations and the results of measurements of humidity profiles.

German abstract:
Über das Wechselspiel einer teilweisen Abdichtung der Oberfläche (Behinderung der Verdunstung in definierten Bereichen), die zeitlich begrenzte Zugabe von Wasser und das Messen der Verdunstung der Feuchtigkeit in einzelnen Höhen kann an einem relativ kleinen Prüfkörper aufsteigende Mauerwerksfeuchte realitätsnah nachgestellt werden. Der Prüfkörper steht über einen langen Zeitraum für Messungen zur Verfügung und wird während dessen nicht verändert. Um zu dieser teilweisen Abdichtung und der temporären Zugabe von Feuchtigkeit zu gelangen, wurden im Vorfeld und zur Überprüfung der Messungen Simulationsrechnungen durchgeführt.
Der Beitrag beinhaltet die Beschreibung des Versuchsaufbaues, die Dokumentation der Simulationsrechnungen und die Ergebnisse zu den entsprechenden Messungen der Feuchtigkeitsprofile.