[Back]


Publications in Scientific Journals:

F. Meirer, G. Pepponi, C. Streli, P. Wobrauschek, N. Zöger:
"Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces";
Journal of Applied Physics, 105 (2009), 074906; 074906-1 - 074906-7.



English abstract:
In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence (GI) setup to compare the performance of both geometries. Furthermore, the investigations were accomplished to gain a better understanding of the so called self-absorption effect, which was observed and investigated in previous studies using a GI geometry. It was suggested that a normal incidence-grazing-exit geometry would not suffer from self-absorption effects in x-ray absorption fine structure (XAFS) analysis due to the minimized path length of the incident beam through the sample. The results proved this assumption and in turn confirmed the occurrence of the self-absorption effect for GI geometry. Due to its lower sensitivity it is difficult to apply the GE geometry to XAFS analysis of trace amounts (few nanograms) of samples but the technique is well suited for the analysis of small amounts of concentrated samples.


"Official" electronic version of the publication (accessed through its Digital Object Identifier - DOI)
http://dx.doi.org/10.1063/1.3106086

Electronic version of the publication:
http://publik.tuwien.ac.at/files/PubDat_174949.pdf


Created from the Publication Database of the Vienna University of Technology.