[Zurück]


Vorträge und Posterpräsentationen (ohne Tagungsband-Eintrag):

B. Huber:
"Physical model test and CFD-simulation of an asymmetrical throttle in a T-shaped junction of a high-head power plant";
Vortrag: IAHR Kongress 2009, Vancouver (eingeladen); 09.08.2009 - 14.08.2009.



Kurzfassung englisch:
Hydraulic model tests were conducted to evaluate the head-losses and flow conditions of
an asymmetrical throttle in a surge chamber system of an Austrian high-head power
plant. The asymmetrical throttle is situated at the beginning of the rising shaft of the
surge tank in one of the three branches of a T-shaped junction. Due to the asymmetrical
shape of the throttle it causes different head-losses between up- and downsurging water
levels.
Several hydraulic model tests with a scale of 1:21 were carried out under different flow
conditions to evaluate the head-losses. Due to the complex shape of the T-junction the
model was milled out of a plastic cube with the help of CNC.
Then, several CFD-simulations were conducted in order to evaluate under which circumstances
the CFD-simulation is able to give reasonable results.

Schlagworte:
Physical model test; T-Junction; Hydraulic experiments; Throttle; CFDsimulation;

Erstellt aus der Publikationsdatenbank der Technischen Universität Wien.