B. Nusser, M. Teibinger, T. Bednar:
"Messtechnische Analyse flachgeneigter hölzerner Dachkonstruktionen mit Sparrenvolldämmung - Teil3: Hinterlüftete und nicht hinterlüftete Metalldächer";
Bauphysik, Volume 32 (2010), Issue 5; 288 - 295.



English abstract:
In the third and last part of this article serial the measuring values of ventilated and non-ventilated metal roofs are discussed. The roofs were investigated at a full scale test under sun-exposed
and full-time shaded conditions. It was shown that at sun-expos -
ed condi tions the vapour retarder membrane in both metal sheet -
ed roofs can be replaced by an OSB without critical climate or increased moisture content in the cavity. The used metal sheeting
at the non-ventilated roofs enables a water vapour permeable
construction. The ventilated metal roof showed in spite of the
little airflow in the ventilation layer the best hygrical behavior of
all investigated roofs.

German abstract:
Im dritten und abschließenden Teil dieser Aufsatzreihe werden
die Messdaten aus hinterlüfteten und nicht hinterlüfteten flachgeneigten Metalldächern diskutiert. Diese wurden im Freilandversuch über 17 Monate unter besonnten und Vollzeit beschatteten Randbedingungen untersucht. Hierbei zeigt sich, dass bei
besonnten Bedingungen in beiden Dachaufbauten die innen -
seitige Dampfbremsbahn durch eine OSB ersetzt werden kann,
ohne dass sich kritische Klimabedingungen oder erhöhte Mate -
rialfeuchten im Gefach einstellen. Die verwendete Gleitbügelblecheindeckung beim nicht hinterlüfteten Dach ermöglicht
einen diffusionsoffenen Aufbau. Das hinterlüftete Metalldach
zeigt trotz geringen Luftvolumenstroms in der Hinterlüftungs -
ebene das günstigste hygrische Verhalten aller untersuchten
Dachauf bauten.