Ch. Heinzl, M. Reiter, E. Gröller, A. Amirkhanov:
"Visual Optimality and Stability Analysis of 3DCT Scan Positions";
IEEE Transactions on Visualization and Computer Graphics, 16 (2010), 6; 1477 - 1486.



English abstract:
Industrial cone-beam X-Ray computed tomography (CT) systems often face problems due to artifacts caused by a bad placement of the specimen on the rotary plate. This paper presents a visual-analysis tool for CT systems, which provides a simulation-based preview and estimates artifacts and deviations of a specimenīs placement using the corresponding 3D geometrical surface model as input. The presented tool identifies potentially good or bad placements of a specimen and regions of a specimen, which cause the major portion of artefacts. The tool can be used for a preliminary analysis of the specimen before CT scanning, in order to determine the optimal way of placing the object. The analysis includes: penetration lengths, placement stability and an investigation in Radon space. Novel visualization techniques are applied to the simulation data. A stability widget is presented for determining the placement parametersī robustness. The performance and the comparison of results provided by the tool compared with real world data is demonstrated using two specimens.