Vorträge und Posterpräsentationen (mit Tagungsband-Eintrag):
J.P. Waclawek, R. Lewicki, H. Moser, M. Brandstetter, F.K. Tittel, B. Lendl:
"Quartz-enhanced photoacoustic spectroscopy based sensor system for sulfur dioxide detection using a CW DFB-QCL";
Poster: IRDG Spring Meeting Vienna,
Wien;
24.04.2014
- 25.04.2014; in: "Program & Poster Abstracts",
(2014),
1 S.
Kurzfassung englisch:
A sensitive, selective and compact gas sensor system based on quartz-enhanced photoacoustic spectroscopy (QEPAS) employing a high power 7.24 µm CW DFB-QCL was developed for detecting SO2 at ppbv concentration levels, suitable for environmental and industrial monitoring. SO2 is a major air pollutant that is mainly released to the atmosphere by industrial combustion processes as well as fuel-based transport activities. SO2 becomes toxic when its concentration exceeds 1 ppmv in ambient air [1]. In this work the influence of H2O vapor addition on monitored QEPAS SO2 signal was also investigated.
Schlagworte:
CW-DFB-QCL, QEPAS, SO2