E. Spunei, I. Piroi, C. Muscai, F. Piroi:
"Automatic block signaling installation failure diagnosis with LCOBla";
Talk: International Conference on Applied and Theoretical Electricity (ICATE) 2014, University of Craiova, Craiova, Romania; 2014-10-23 - 2014-10-25; in: "Proceedings of the 2014 International Conference on Applied and Theoretical Electricity (ICATE)", IEEExplore, (2014), ISBN: 978-1-4799-4161-2; 1 - 6.



English abstract:
We present in this paper a software module for the diagnosis of Automatic Bloc Signaling installation failures in situations where the train open line figures as blocked, although it is, in reality, free. The software module created by us, LCOBla, is designed for the use of maintenance staff specialized in Signals, Centralizations, Blocking (SCB) at the Romanian Railroad Company (CFR). LCOBla allows a quick and correct design of the failure causes associated with these kinds of signaling and contributes to the maintenance staff performance. Fast failure remedy improves train traffic flow and reduces train delay times. The LCOBla software module uses the diagnosis chart created for these kinds of failures, which, in turn, is based on the actual block schemes and on technical recommendations for these types of installations. The module is one of a series of modules designed to diagnose each failure type, for the various railway traffic safety installation types.

Keywords:
rail traffic, railway safety, system recovery


"Official" electronic version of the publication (accessed through its Digital Object Identifier - DOI)
http://dx.doi.org/10.1109/ICATE.2014.6972680

Electronic version of the publication:
http://publik.tuwien.ac.at/files/PubDat_236568.pdf


Created from the Publication Database of the Vienna University of Technology.