I. Piroi, E. Spunei, C. Muscai, F. Piroi:
"Diagnosis charts for regular inversion failures of an Automatic Block Signal Installation";
Talk: International Conference on Applied and Theoretical Electricity (ICATE) 2014, University of Craiova, Craiova, Romania; 2014-10-23 - 2014-10-25; in: "Proceedings of the 2014 International Conference on Applied and Theoretical Electricity (ICATE)", IEEExplore, (2014), ISBN: 978-1-4799-4161-2; 1 - 4.



English abstract:
In train traffic, traffic security installations failure recovery is time consuming, causing time delays the the railroad traffic. Automatic Block Signal Installations (ABS) are on type of installations that ensure railroad traffic security. To decrease the failure diagnosis and remedy times for ABS Installations in cases where the installations do not regularly invert, we defined a set of diagnosis charts. Based on these charts we devised a diagnosis software tool, called INVBla, which can be used by the technical maintenance staff on both mobile devices (tablet, smart phone) and PCs. The use of the INVBla diagnosis tool is a fast and secure tool that assists the maintenance staff in determining the failures in ABS regular inversion, triggered by dispatch commands, for a unified ABS installation depending on an Electrodynamic Centralized Traffic Control Station of type 4 (CED-CR4).

Keywords:
fault diagnosis, rail traffic control, railway communication, software tools, telecommunication signalling


"Official" electronic version of the publication (accessed through its Digital Object Identifier - DOI)
http://dx.doi.org/10.1109/ICATE.2014.6972681

Electronic version of the publication:
http://publik.tuwien.ac.at/files/PubDat_236584.pdf


Created from the Publication Database of the Vienna University of Technology.