Zeitschriftenartikel:
H. Pfützner, G. Shilyashki:
"Magnetic Dummy Sensors - A Novel Concept for Interior Flux Distribution Tests";
International Journal of Applied Electromagnetics and Mechanics,
vol 48
(2015),
no 2,3;
S. 213
- 218.
Kurzfassung englisch:
The paper describes a novel concept for the determination of 3-dimensional interior flux distributions in laminated magnetic cores. Magnetic dummy sensors - e.g. calibrated in Epstein testers - yield local values of induction in a tangential way or in thin channels, respectively.
Schlagworte:
Magnetic sensors, induction distribution, transformer cores