[Zurück]


Zeitschriftenartikel:

M. Fuerst, S. Unger, S. Ito, G. Schitter:
"Wavefront measurement based feedback control for automatic alignment of a high-NA optical system";
Journal of Physics: Conference Series, 1065 (2018), 4 S.



Kurzfassung englisch:
Many applications of optical systems depend on focal spot quality, which depends
on the alignment of the optical components. During alignment, it is difficult to monitor the spot
quality because the spot position shifts with the alignment. This paper proposes to compensate
for displacements of the focal spot and to monitor the spot quality by controlling the position of
a Shack-Hartmann sensor. Low-order aberration data is used to control the position of a Shack-
Hartmann sensor while higher-order aberrations are used to estimate focal spot quality. An
experimental high numerical aperture setup is presented and the proposed method is applied.
The experimental results successfully demonstrate the automatic alignment capabilities.


"Offizielle" elektronische Version der Publikation (entsprechend ihrem Digital Object Identifier - DOI)
http://dx.doi.org/10.1088/1742-6596/1065/3/032001

Elektronische Version der Publikation:
https://publik.tuwien.ac.at/files/publik_273524.pdf