[Zurück]


Vorträge und Posterpräsentationen (mit Tagungsband-Eintrag):

J. Dorazil, R. Repp, T. Kropfreiter, R. Prüller, K. Riha, F. Hlawatsch:
"Feature drift resilient tracking of the carotid artery wall using unscented Kalman filtering with data fusion";
Vortrag: 2020 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Barcelona Spain (virtual); 04.05.2020 - 08.05.2020; in: "Ieee Icassp 2020", IEEE, (2020), ISBN: 978-1-5090-6631-5; S. 1095 - 1099.



Kurzfassung englisch:
An analysis of the motion of the common carotid artery (CCA) provides effective indicators for cardiovascular diseases. Here, we propose a method for tracking CCA wall motion from a B-mode ultrasound video sequence. An unscented Kalman filter based on a suitably devised state-space model fuses measurements produced by an optical flow algorithm and a CCA wall localization algorithm. This approach compensates for feature drift, which is a detrimental effect in optical flow algorithms. The proposed method is demonstrated to outperform a state-of-the-art tracking method based on optical flow.

Schlagworte:
Atherosclerosis, common carotid artery, B-mode ultrasound, unscented Kalman filter, data fusion


"Offizielle" elektronische Version der Publikation (entsprechend ihrem Digital Object Identifier - DOI)
http://dx.doi.org/10.1109/ICASSP40776.2020.9054703

Elektronische Version der Publikation:
https://publik.tuwien.ac.at/files/publik_292215.pdf