Ventilated windows have the potential to contribute to both indoor air quality and energy efficiency in cold climates. A typical ventilated window functions as a solar collector under inward air flow direction and incident solar radiation. The ventilated window is a modification of the multiple pane windows in which air is drawn in from outside and is heated through conduction, convection, and radiation in the cavity. In this study, a detailed parametric analysis was conducted to investigate the thermal performance of ventilated windows and their capacity to preheat ventilation air. High-resolution 3D steady RANS computational fluid dynamic (CFD) simulations were performed for six ventilated window geometries. Model results were compared with measurements. The following geometric characteristics were evaluated in detail: (i) The height of the window, (ii) the width of the cavity, (iii) the location of double-layered glazing, and (iv) the width of the supply air opening. The results suggested that taller cavities and a smaller cavity depth can provide higher incoming air temperature. Windows with inner double-layered glazing and a smaller width of supply air opening displayed a better thermal performance.

Kurzfassung englisch:
Ventilated windows have the potential to contribute to both indoor air quality and energy efficiency in cold climates. A typical ventilated window functions as a solar collector under inward air flow direction and incident solar radiation. The ventilated window is a modification of the multiple pane windows in which air is drawn in from outside and is heated through conduction, convection, and radiation in the cavity. In this study, a detailed parametric analysis was conducted to investigate the thermal performance of ventilated windows and their capacity to preheat ventilation air. High-resolution 3D steady RANS computational fluid dynamic (CFD) simulations were performed for six ventilated window geometries. Model results were compared with measurements. The following geometric characteristics were evaluated in detail: (i) The height of the window, (ii) the width of the cavity, (iii) the location of double-layered glazing, and (iv) the width of the supply air opening. The results suggested that taller cavities and a smaller cavity depth can provide higher incoming air temperature. Windows with inner double-layered glazing and a smaller width of supply air opening displayed a better thermal performance.

Schlagworte:
ventilated window; energy performance; heat transfer; optimal design


"Offizielle" elektronische Version der Publikation (entsprechend ihrem Digital Object Identifier - DOI)
http://dx.doi.org/10.3390/en14092420

Elektronische Version der Publikation:
https://www.mdpi.com/1996-1073/14/9/2420


Erstellt aus der Publikationsdatenbank der Technischen Universität Wien.