H. Teufl, M. Schuss, A. Mahdavi:
"Laboratory tests of a prototypical user-centric radiant cooling solution";
Journal of Physics: Conference Series, 2069 (2021), 012122.



English abstract:
Radiant cooling systems are being increasingly promoted because of their energy efficient operation as well as their potential to improve occupants' thermal comfort due to a draft-free cooling process. This paper focuses on a specific radiant cooling approach, which was introduced in previous contributions. This approach involves the positioning of relatively small-sized vertical radiant panels in the close proximity to occupants. Furthermore, the panels incorporate drainage systems or collection elements to accommodate, if needed, water vapour condensation. Consequently, the surface temperature of the radiant panels does not need to stay above the dew point temperature. We present the outcome of a preliminary experimental investigation of such a personal radiant cooling system. In this context, prototypical radiant panels were installed in a laboratory and multiple experiments were conducted. The uniformity level of the panels' surface temperature distribution was documented. Moreover, near-panel air flow velocities were measured at several positions. Likewise, the formation of condensed water on panels was observed for different panel surface temperatures, room temperatures, and room humidity levels. The results of the preliminary laboratory investigation do not point to any risk of draft or turbulence discomfort.

German abstract:
(no german Abstract):
Radiant cooling systems are being increasingly promoted because of their energy efficient operation as well as their potential to improve occupants' thermal comfort due to a draft-free cooling process. This paper focuses on a specific radiant cooling approach, which was introduced in previous contributions. This approach involves the positioning of relatively small-sized vertical radiant panels in the close proximity to occupants. Furthermore, the panels incorporate drainage systems or collection elements to accommodate, if needed, water vapour condensation. Consequently, the surface temperature of the radiant panels does not need to stay above the dew point temperature. We present the outcome of a preliminary experimental investigation of such a personal radiant cooling system. In this context, prototypical radiant panels were installed in a laboratory and multiple experiments were conducted. The uniformity level of the panels' surface temperature distribution was documented. Moreover, near-panel air flow velocities were measured at several positions. Likewise, the formation of condensed water on panels was observed for different panel surface temperatures, room temperatures, and room humidity levels. The results of the preliminary laboratory investigation do not point to any risk of draft or turbulence discomfort.


"Official" electronic version of the publication (accessed through its Digital Object Identifier - DOI)
http://dx.doi.org/10.1088/1742-6596/2069/1/012122

Electronic version of the publication:
https://iopscience.iop.org/article/10.1088/1742-6596/2069/1/012122


Created from the Publication Database of the Vienna University of Technology.