[Zurück]


Vorträge und Posterpräsentationen (mit Tagungsband-Eintrag):

I. Ignat, B. Schuster, J. Hafner, M. Kwon, D. Platz, U. Schmid:
"Mechanical cooling of AFM cantilevers";
Vortrag: Mikrosystemtechnik-Kongress 2021, Ludwigsburg, Deutschland; 08.11.2021 - 10.11.2021; in: "Mikrosystemtechnik-Kongress 2021", VDE-Verlag, (2021), ISBN: 978-3-8007-5656-8; Paper-Nr. D3.2, 4 S.



Kurzfassung englisch:
We have investigated techniques applicable to current standard atomic force micorscopy. Using intermodal coupling in
commercially available cantilevers, we have proven that it is possible to reduce the Q factor of the cantilever´s first vibra-
tional mode (ω1 = 2π× 68.787 KHz) from 17500 to 12000. Simultaneously, the effective temperature of the mode was
reduced by an order of magnitude from room temperature. This is possible by coupling the first and the second flexural
mode (ω2 = 2π× 438.04 KHz) with an excitation tone at their eigenfrequency difference (ωp = 2π× 369.253 KHz).