C. Harreither, J. Gengler, T. Bednar:
"Comparison of indoor moisture excess in three different terraced housing projects";
Talk: 8th International Buildings Physics Conference 2021 (IBPC 2021), Kopenhagen, Dänemark; 2021-08-25 - 2021-08-27; in: "Journal of Physics: Conference Series", IOP Publishing, 2069 (2021), 1 - 9.



English abstract:
In this study three neighbourhoods of terraced houses have been investigated. In 16 to 29 houses of each project, indoor temperature and indoor humidity have been measured, inhabitants have been interviewed and Blower-Door Tests have been performed. PSG is a project with 91 similar, very airtight detached houses. More than 29 of these houses have been investigated. TES is a low-rise high-density project with 46 single family houses built in 1974. The measuring results of 20 houses with very poor airtightness have been analysed. APW is a project with 26 terraced houses built in 2012, which have mechanical ventilation systems. From APW 16 houses have participated in the study. It will be illustrated that the airtight houses of PSG have the highest absolute indoor humidity, the TES houses with the poor airtightness have medium absolute indoor humidity and the APW with the mechanical ventilation systems have the lowest absolute indoor humidity. Box plots of the moisture excess in the diagram with the humidity classes from EN ISO 13788 [1] show that the boxes do not overlap.


"Official" electronic version of the publication (accessed through its Digital Object Identifier - DOI)
http://dx.doi.org/10.1088/1742-6596/2069/1/012041

Electronic version of the publication:
https://publik.tuwien.ac.at/files/publik_302631.pdf


Created from the Publication Database of the Vienna University of Technology.